Roof Underlayment Explained: What Sits Under Your Shingles and Why It Matters

Roof underlayment is the layer you never see once a roof is finished. It sits between the wooden roof deck and the shingles, and it is the second line of defence when wind, hail or age lets water past the surface. On a replacement quote it often appears as a single line, which makes it easy to skim past.

This guide explains what underlayment does, the main types, where the special waterproof kind goes, and why the choice matters in North Texas storms. It sticks to what the asphalt roofing industry, building science researchers and manufacturers publish. There are no prices here, and nothing a homeowner should do on the roof.

What is roof underlayment, and what does it do?

Roof underlayment is a sheet of water-resistant material laid over the roof deck before the shingles go on. The Asphalt Roofing Manufacturers Association describes it as secondary protection from water intrusion. It keeps the deck dry during installation and backs up the shingles if water gets under them later.

ARMA’s guide to the asphalt shingle roofing system defines underlayment as sheets of water-resistant material that provide secondary protection from water intrusion, installed between the roof deck and the shingles. It adds that many underlayments are slip resistant, which makes the work safer for roofers.

The ARMA residential asphalt roofing manual lists the practical reasons it is installed:

  1. Backup protection. With the shingles, it shields the deck from wind-driven rain and keeps water from reaching the wood.
  2. A dry deck during the job. It keeps the deck dry until shingles are applied, which avoids problems from shingling over a wet deck.

The Insurance Institute for Business & Home Safety (IBHS) puts it plainly in its sealed roof deck guidance. If shingles are damaged or worn, the underlayment should act as a secondary barrier against water entering through gaps in the wood deck.

Think of a roof as layers: framing, then the deck of plywood or OSB, then underlayment, then shingles, with flashing at the joints. The shingles take the weather. The underlayment catches what the shingles miss.

Is roof underlayment required by code?

Yes. Underlayment is part of the building code for shingle roofs, and the material has to meet recognised standards. Atlas Roofing notes that underlayment is required by the International Residential Code and local codes and must meet certain ASTM standards. In Plano, a reroof is carried out under the city’s adopted 2024 International Residential Code.

Plano adopted the 2024 IRC with local amendments through Ordinance No. 2025-6-15. We found no local amendment in that ordinance adding a hail-specific underlayment requirement, so the base code applies.

Atlas Roofing makes the code point in its guide to felt and synthetic roof underlayment. ARMA’s manual lists the consensus standards that North American building codes reference for underlayment beneath shingles:

StandardWhat it covers, per ARMA and Atlas
ASTM D226Asphalt-saturated felt
ASTM D4869Asphalt-saturated felt
ASTM D6757Inorganic shingle underlayment (Atlas cites it for synthetic products)
ASTM D1970Self-adhering shingle underlayment

ARMA tells installers to consult local codes and the shingle manufacturer’s recommendations for the specific standard. When you read a quote, the product’s data sheet should name the standard it meets.

A 2016 City of Plano re-roof handout also said that metal panel, metal shingle, concrete and clay tile roofs need a non-combustible underlayment. That handout predates the current code, so confirm today’s rule with Plano Building Inspections before relying on it.

What types of roof underlayment are there?

There are three main types. Asphalt-saturated felt is the traditional product. Synthetic underlayment is a woven polymer sheet that has largely taken over. Self-adhering underlayment, often called ice and water membrane, is a sticky, rubberised sheet used in the most vulnerable spots. Many roofs use more than one type.

ARMA’s manual notes that felt was historically specified, but there are now many synthetic underlayments available, some self-adhering and some not. CertainTeed’s homeowner explainer on shingle underlayment says synthetic products have emerged as the preeminent underlayment used today.

TypeWhat it isWhere it is used
Asphalt-saturated feltOrganic or fiberglass mat soaked in asphalt; sold as #15 or #30, per AtlasField of the roof, especially on older or budget specifications
SyntheticWoven polypropylene sheet, per AtlasField of the roof on most current replacements
Self-adhering (ice and water)Polymer modified bituminous sheet, per ARMAEaves, valleys, around chimneys and skylights, low-slope areas

The difference between felt and synthetic is the most common question. Our side-by-side comparison of synthetic underlayment vs felt covers weight, strength, wrinkling, exposure and how each suits a Plano roof.

Where does self-adhering underlayment go on a roof?

Self-adhering underlayment goes where water is most likely to back up or be driven sideways: valleys, eaves, rake edges, around chimneys, skylights and dormers, at slope changes and on low-slope sections. ARMA lists these as the critical areas. It is stuck directly to the deck, so it seals around nails.

ARMA’s manual describes these products as polymer modified bituminous membranes that can be used in place of, or in addition to, standard underlayment in critical areas. They resist water penetration from ice dams and wind-driven rain.

Ice dams are rare in Plano, so the eave use matters less here than in a snow climate. ARMA makes a point that does apply locally. It says self-adhering underlayment can also be useful in warmer climates where water backs up behind accumulated pine needles, leaves and other roof debris.

CertainTeed describes the modern approach as two underlayments working together. A waterproof ice and water membrane goes along the perimeter and in valleys, where roof planes meet and channel heavy water flow, and around penetrations. A synthetic underlayment covers the rest.

There is a caution in ARMA’s guidance. It warns that self-adhering sheets and other low-permeability products can act as vapour retarders and trap moisture between the covering and the deck when the deck is not properly ventilated. More membrane is not automatically better. Ventilation has to be right.

Why does underlayment matter for Plano hail and storms?

North Texas storms combine hail, high wind and heavy rain, and each one can open a path through the shingles. When that happens, the underlayment is what stands between the water and the wood. IBHS research shows that a well-detailed underlayment layer can keep a damaged roof from turning into a soaked attic.

According to the NOAA Storm Events Database, the Plano area logged 310 hail reports on 62 separate days between 2016 and 2025. Hail of 2 inches or larger was reported on 17 of those days, all between March and June or in September.

IBHS warns in its sealed roof deck guidance that in high winds, standard underlayment alone may not be enough, especially if it is thin, stapled on or poorly installed. It recommends one of three methods for new roofs and reroofs:

  1. Roof flashing tape at least 4 inches wide over all deck seams, then #30 felt or a reinforced synthetic underlayment over the whole deck.
  2. A fully adhered membrane over the entire deck.
  3. Two layers of underlayment, #30 felt or synthetic, with a 50% overlap, secured with 1-inch button cap nails.

Ask your roofer whether the quote includes any of these. A sealed roof deck is an upgrade, not a code minimum, so it should be listed and explained.

What does roof underlayment look like on a quote?

On a replacement quote, underlayment should be named by product and type, not just “underlayment.” Look for the field material, the self-adhering areas, and how it is fastened. The quote should say whether a sealed roof deck method is included. Vague wording makes it impossible to compare two bids fairly.

A clear quote answers these questions:

QuestionWhat a clear answer looks like
What covers the field of the roof?Product name and type, felt weight or synthetic
Which standard does it meet?ASTM D226, D4869, D6757 or D1970 as appropriate
Where does self-adhering membrane go?Valleys, eaves, rakes, penetrations, low-slope areas listed
How is it fastened?Cap nails or the manufacturer’s stated method
Is a sealed roof deck included?Which IBHS method, or a clear “no”
Does it match the shingle warranty?Underlayment approved by the shingle maker

ARMA’s manual also notes that overlaps and fasteners for synthetic underlayment vary by product and should follow the manufacturer’s minimums. A roofer should be able to show you the product’s instructions.

When the old roof comes off, the deck itself is exposed, and rain during that window is a common worry. Our guide to how long underlayment can stay exposed in rain covers that stage of the job.

How does slope change the underlayment a roof needs?

Slope decides how many layers go down. ARMA says decks with a slope of 4 inches per foot or more should get one layer of non-perforated underlayment. Shingles on slopes from 2:12 up to 4:12 need special low-slope procedures, traditionally two layers of felt. Below 2:12, shingles are not the right covering at all.

ARMA’s manual describes the traditional low-slope method as two layers of non-perforated asphalt-saturated felt, starting with a 19-inch strip along the eave and lapping each following course over it. Many installers now use self-adhering membrane on low-slope areas instead, as ARMA’s critical-areas list allows.

Plano homes often mix slopes. A steep main roof can sit beside a shallow porch roof or a low addition. Each part needs the underlayment its slope calls for, and sections flatter than 2:12 need a membrane roof rather than shingles.

Roof slopeUnderlayment approach, per ARMA
4:12 and steeperOne layer of non-perforated underlayment
2:12 to below 4:12Special low-slope procedures, traditionally two layers of felt
Below 2:12Not a shingle roof; needs a membrane system

Ask your roofer to confirm the slope of each roof plane and how the underlayment changes across them. For the bigger picture of a replacement, from materials to solar and timing, see our guide to planning a reroof in Plano. When you are ready for quotes, Roofing Repair Plano handles full tear-offs through our roof replacement service.

Frequently asked questions

What does roofing underlayment do?

Underlayment is a water-resistant sheet between the roof deck and the shingles. ARMA calls it secondary protection from water intrusion. It keeps the deck dry while the roof is being installed, and it backs up the shingles if wind-driven rain, hail damage or age lets water past them. It is a required part of a shingle roof.

What is the best roofing underlayment?

There is no single best product. Most current replacements use a synthetic underlayment over the field of the roof, with self-adhering membrane in valleys, at edges and around penetrations. The right choice also depends on slope, ventilation and what the shingle manufacturer approves. Ask for named products that meet the relevant ASTM standard.

Can roof underlayment get wet?

Underlayment is water-resistant by design, so rain on it during a job is expected. ARMA says one of its jobs is keeping the deck dry until shingles go on. It is not meant to be the permanent roof, though, and manufacturers set limits on how long it can stay exposed. Ask your roofer what the product allows.

Can you put roof underlayment on wet plywood?

It should not be done. ARMA says underlayment keeps the deck dry until shingles are applied, minimising problems that come from roofing over a wet deck. A wet deck that is sealed in can hold moisture. If rain interrupts a tear-off, the roofer should let the deck dry, or replace damaged boards, before covering it.

Is 30 lb felt or synthetic underlayment better?

Atlas Roofing says synthetic is slightly more expensive than felt but lighter and stronger, and it cites InterNACHI on felt wrinkling and UV breakdown. Both can meet code. Synthetic is the common choice today, while #30 felt still appears in some IBHS sealed roof deck methods. Our felt vs synthetic guide compares them in detail.