Synthetic roof underlayment and asphalt-saturated felt do the same basic job. Both sit between the roof deck and the shingles and back the roof up when water gets past the surface. They are built very differently, though, and a replacement quote will usually name one or the other.
This guide compares the two on the points that matter on a Plano house: what each is made of, strength and weight, wrinkling, how long each tolerates sun and rain during a job, moisture, and code. Every claim comes from a named industry source, and manufacturer claims are labelled as such. There are no prices, only how the cost difference is described.
What is the difference between synthetic roof underlayment and felt?
Felt is a paper or fiberglass mat soaked in asphalt, sold in #15 and #30 weights. Synthetic roof underlayment is a woven polypropylene sheet. Atlas Roofing, which makes both, describes synthetic as thinner, stronger and lighter, and felt as cheaper and long established. Both can meet the building code when the product carries the right standard.
Atlas explains the materials in its guide to felt and synthetic roof underlayment. Felt, also called tarpaper, dates to the early 20th century. It is made from organic cellulose or inorganic fiberglass, saturated with asphalt to reduce vapour permeability. Synthetic is woven polypropylene fabric.
| Feature | Asphalt-saturated felt | Synthetic underlayment |
|---|---|---|
| Base material | Cellulose or fiberglass mat saturated with asphalt | Woven polypropylene |
| Common grades | #15 basic and #30 heavy, per Atlas | Varies by product |
| Code standards cited | ASTM D226 and D4869 | ASTM D6757 for Atlas’s synthetic |
| Relative cost, per Atlas and CertainTeed | Lower | Somewhat higher |
| Wrinkling when wet | A known problem, per InterNACHI via Atlas | Lies flatter, per CertainTeed |
| Vapour permeability | Allows some moisture through, per Atlas | Not permeable, per Atlas |
The Asphalt Roofing Manufacturers Association (ARMA) frames the shift in its residential asphalt roofing manual. Felt was historically specified, it says, but many synthetic underlayments are now available. For the basics of what any underlayment does, see our guide to roof underlayment explained.
Is 30 lb felt or synthetic roof underlayment better?
For most Plano reroofs, synthetic has the practical edge: it is lighter, stronger, lies flatter and handles exposure during the job better. Number 30 felt is still a code-compliant product and still appears in building science guidance. The better choice depends on the shingle maker’s approved list, the roof’s ventilation and how the roofer installs it.
The case for synthetic, as manufacturers state it:
- Strength and weight. Atlas says its own Summit synthetic is six times lighter and three times stronger than #30 felt. That is a manufacturer claim about one product, not every synthetic.
- Flatness. CertainTeed’s homeowner guide to shingle underlayment says synthetics are better at lying flat, which prevents wavy shingle installations.
- Water resistance. CertainTeed says synthetics offer superior water resistance, enough that high-end products can serve as short-term temporary roof covers.
The case for felt is cost and familiarity. Atlas says many roofers still prefer felt because of its low cost and long track record.
Felt is not obsolete in good practice either. The Insurance Institute for Business & Home Safety (IBHS) includes #30 felt alongside reinforced synthetic in its sealed roof deck methods. A well-installed #30 felt roof can outperform a badly installed synthetic one.
Why does felt wrinkle, and does it matter?
Felt wrinkles because it absorbs moisture and expands. Atlas cites InterNACHI, the home inspectors’ association, listing wrinkling from expansion as a known felt problem, along with weakening from UV exposure. Wrinkles under shingles can show through as ripples. The fix is covering felt quickly and keeping it dry, which is not always possible in storm season.
According to Atlas, felt allows some moisture to permeate over time, and that can lead to problems with the roof deck. It says felt cannot be left on the roof for long before it needs to be covered by shingles.
ARMA’s installation manual underlines why flatness matters. It says underlayment in valleys should lie tight and should not be creased or wrinkled, and that during reroofing, any wrinkling or uneven surface can show through new shingles.
CertainTeed makes the same point from the synthetic side. It says synthetics lie flatter, which prevents a wavy finished roof.
On a dry, quick job, felt wrinkling may never become an issue. On a job interrupted by a spring storm, a felt-covered deck that gets soaked before shingles go on is more likely to need attention before the roof is finished.
How long can each type stay exposed before shingles go on?
Synthetic tolerates much longer exposure than felt. Atlas cites Green Building Advisor as saying synthetic polypropylene can be exposed to UV and weather for up to six months before shingles are installed. Atlas says felt cannot be left on the roof for long. Always follow the specific product’s stated exposure limit, which the manufacturer sets.
Exposure matters because reroofs do not always run on schedule. Material delays, crew scheduling and weather can leave underlayment uncovered for days.
| Exposure question | Felt | Synthetic |
|---|---|---|
| UV tolerance | Weakens with UV exposure, per InterNACHI via Atlas | Up to six months for some products, per Green Building Advisor via Atlas |
| Rain during the job | Absorbs moisture and can wrinkle | Atlas says it is more effective as a temporary weather barrier |
| Who sets the limit | The felt manufacturer | The synthetic manufacturer, by product |
The six-month figure is not a promise for every synthetic. Product data sheets set the limit, and a roofer should know it for the product on your roof.
Rain during a tear-off is a separate worry from long exposure. Our guide to how long underlayment can stay exposed in rain covers what should happen if a storm hits mid-job.
Which suits Plano heat, hail season and storms?
Plano reroofs often run in hail season, when storms come fast and crews are busy. That favours an underlayment that stays flat and tolerates rain and sun if the job is interrupted. Synthetic generally does that better. Summer heat also argues for synthetic, since ARMA notes temperature conditions may warrant its use.
According to the NOAA Storm Events Database, the Plano area logged 310 hail reports on 62 separate days between 2016 and 2025. Hail of 2 inches or larger was reported on 17 of those days, all between March and June or in September. Those are also busy reroofing months, and a job can be caught by the next storm.
ARMA’s manual says ambient temperature conditions may warrant a synthetic underlayment, with or without a self-sealing feature, or a self-adhering underlayment. It does not name a climate, but the point stands in a hot summer.
The bigger storm decision is not felt versus synthetic. IBHS warns that in high winds, standard underlayment alone may not be enough, especially if it is thin, stapled on or poorly installed. Its three sealed roof deck methods work with either material:
- 4-inch self-adhering tape over deck seams, then #30 felt or reinforced synthetic over the whole deck.
- A fully adhered membrane over the whole deck.
- Two layers of #30 felt or synthetic with a 50% overlap, fastened with 1-inch button cap nails.
Does synthetic underlayment trap moisture in the attic?
It can, if the attic is poorly ventilated. Atlas says synthetic polypropylene is not permeable by moisture or vapour. ARMA warns that low-permeability products can act as vapour retarders, trapping moisture between the roof covering and the deck when the deck is not properly ventilated. Good ventilation, not the underlayment alone, prevents that.
ARMA’s warning names asphalt-coated base sheets, self-adhering underlayments, polyethylene sheets and laminated waterproof papers. It tells installers to consult each manufacturer for recommendations when using them.
Felt’s permeability cuts both ways. Atlas says felt lets some moisture through over time, which can harm the deck. A synthetic blocks that path, so any moisture rising from the house has to leave through attic ventilation instead.
The practical step is simple. Ask the roofer to check intake and exhaust ventilation as part of the quote, whatever underlayment is chosen.
Does the underlayment choice change how the job is installed?
It changes the details more than the sequence. Synthetic rolls are larger and lighter, and Atlas cites Green Building Advisor on their slip resistance for workers. Felt is heavier per roll and tears more easily. Either way, overlaps, fastener type and spacing come from the product’s instructions, and a careful crew follows them on every course.
ARMA’s guide to the asphalt shingle roofing system notes that many underlayments are slip resistant to provide safer working conditions for roofers. That is a crew safety feature, and it is one reason homeowners should never walk a freshly papered roof themselves.
ARMA’s manual sets a few rules that apply whatever the material:
- lay courses parallel to the eaves;
- lap each course at least 2 inches over the one below;
- follow the manufacturer’s minimum overlaps and fasteners for synthetics, which vary by product;
- check local code for specific underlayment and fastener requirements.
The practical takeaway is that the product and the installer go together. A premium synthetic stapled loosely in a hurry gives up much of its advantage. Ask how it will be fastened, and look at the roof from the ground before shingles go on if the crew invites you to.
What should you ask your roofer about underlayment?
Ask which product goes on, by name, and whether the shingle manufacturer approves it. Ask about the standard it meets, how it is fastened, its exposure limit, and whether a sealed roof deck is included. Those answers tell you far more than the words “felt” or “synthetic” alone. A roofer should answer all of them readily.
Use this checklist when you compare quotes:
- Product name and type. Not just “synthetic” or “30 lb felt.”
- Standard. ASTM D226 or D4869 for felt; ASTM D6757 or the maker’s stated standard for synthetic.
- Shingle maker approval. Is this underlayment accepted under the shingle warranty?
- Fastening. ARMA says synthetic overlaps and fasteners vary by product and should follow the manufacturer’s minimums.
- Exposure limit. How long can it stay uncovered, and what happens if the job stops?
- Self-adhering areas. Valleys, eaves, rakes and penetrations listed.
- Sealed roof deck. Which IBHS method, if any.
- Ventilation check. Was it looked at, and does it need work?
For how underlayment fits the rest of the job, from materials to solar and timing, see our guide to planning a reroof in Plano. If you want a quote that spells out the underlayment line by line, Roofing Repair Plano provides that through our roof replacement service.
Frequently asked questions
Which is better for roofing, 30 lb felt or synthetic underlayment?
Synthetic is the more common choice today. Atlas and CertainTeed say it is lighter, stronger, lies flatter and resists water better, though it costs somewhat more. Number 30 felt still meets code and appears in IBHS sealed roof deck methods. Installation quality and the shingle maker’s approval matter as much as the material.
Is synthetic underlayment worth the extra cost?
For most reroofs, manufacturers argue yes, because it handles exposure, rain and foot traffic during installation better than felt. Atlas describes it as slightly more expensive. The benefit is largest when a job could be interrupted by weather, which is common in North Texas hail season. Ask for the cost difference itemised on the quote.
How long can synthetic underlayment be exposed?
It depends on the product. Atlas cites Green Building Advisor as saying synthetic polypropylene can be exposed for up to six months before shingles go on. Felt tolerates far less, and Atlas says it cannot be left uncovered for long. Ask your roofer for the exposure limit printed on the exact product used.
Does synthetic underlayment need attic ventilation?
Yes. Atlas says synthetic is not permeable by moisture or vapour, and ARMA warns that low-permeability layers can trap moisture between the covering and the deck when the deck is not properly ventilated. Proper intake and exhaust ventilation lets moisture leave the attic. Ask for a ventilation check with any reroof quote.
Can felt and synthetic be used on the same roof?
Yes, in the sense that most roofs already mix types. Self-adhering membrane goes in valleys, at edges and around penetrations, with felt or synthetic across the field. CertainTeed describes this two-underlayment approach as standard modern practice. Ask your roofer which product goes where, and why.






